News - Breezy Med

Software Release: New Fogging Protocols and an Improved Breezy Smart Controller App

Written by Breezy Product Team | Feb 2, 2026 2:59:56 AM

Coming in the second week of February, we’re releasing a major software update for Breezy Blue that introduces new fogging protocols and a fully redesigned Breezy Smart Controller app UI (v3.0.0). These changes are driven directly by real-world clinical use, customer feedback, and internal biological indicator (BI) testing—and they represent one of the most meaningful workflow improvements we’ve made to Breezy Blue to date.

Smart Controller Compatibility
This update applies only to Gen2 Breezy Smart Controllers.
Gen1 Smart Controllers are not affected and will continue to operate with existing fogging protocols and UI.

Introducing Two Fogging Modes: Quick and Full

This release introduces two distinct fogging modes:

  • Quick Mode (existing behavior):
    Breezy Blue fogs the same way it has historically. Operators manually set fogging time based on room volume, using offline formulas or the Breezy fogging time calculator.

  • Full Mode (new):
    Breezy Blue automatically manages fog generation and total treatment time based on room size and target log reduction, with no calculations required by the user.
 
Full Mode was developed in response to hospital use cases where coverage consistency matters most, including:
  • Disinfection of privacy curtains
  • Larger or oddly shaped spaces where airflow is unpredictable
  • Higher log-reduction protocols
 

Why Full Mode is Different

Full Mode intentionally slows the fog generation rate, extending fogging time up to ~5 minutes (compared to ~30 seconds to 2 minutes in Quick Mode). This slower humidity ramp improves droplet circulation and room-wide distribution while reducing the chance of condensation, especially in larger spaces.

Quick Mode is still useful for very small spaces (<500 cu ft) where fogging times are very short. Examples include:
  • Transport vehicles
  • Small restrooms
 

For most healthcare applications, especially larger rooms or higher log reductions, Full Mode is recommended.

Predictable, Standardized Treatment Times

In Full Mode, total treatment time is predictable and standardized, based on internal BI testing conducted under real-world conditions. Users no longer need to understand fogging-time formulas—they simply select Room Size (S, M, L, XL) and Desired Log Reduction (4, 5, or 6). Breezy Blue handles the rest.

Full Mode total treatment times are shown in the table below, which will be documented in the app and the user's manual. These times are designed so EVS teams know exactly when to return to retrieve the device, simplifying scheduling and staffing.

Pathogen Reduction

Small

(0-1500 ft3)

Medium

(1500-2500 ft3)

Large

(2500-4000 ft3)

X-Large

(4000-6000 ft3)

4-log

15

15

15

15

5-log

15

15

15

20

6-log

25

25

25

25

Table 1. Full Mode treatment times (in minutes)

These protocols are informed by internal BI testing in real-world environments. While results depend on proper use and conditions, Full Mode is designed to provide consistent, repeatable performance.

Overhauled Breezy Smart Controller App UI

To support these new protocols, the Breezy Smart Controller app has been fully redesigned with a focus on consistency, simplicity, and reduced user error. The following screenshots show some of the most important changes to the new layout and UI improvements.


Updated Top Push Button Behavior (Important Change)

The operation of the top push button on Breezy Blue has been redesigned to eliminate confusion and reduce operator error.

Previously, the top button acted as a toggle. When push-button fogging was enabled, this could conflict with controller-based operation. With this release, the top push button starts a fog cycle when pressed three times in quick succession. This change aligns the top button with controller-based workflows. The top button can still be enabled or disabled in the app, but most users will leave it enabled and benefit from the consistent behavior. Additional information about setting up and using the push-button are described within the Smart Controller Quick Start Guide.

Part of a Broader Breezy Roadmap

These updates are part of our broader roadmap to continue improving Breezy as the fastest, most practical method for whole-room deep disinfection, with 15 minutes of total treatment time for most healthcare applications—while making operation simpler and more consistent for frontline staff.

Availability and Next Steps

This software update will be available shortly (second week of February).
We recommend all customers review the updated Breezy Blue Quick Start Guide and Smart Controller Quick Start Guide to understand the new modes and UI changes before deploying them operationally.

If you have questions about how to apply Full Mode within your specific workflows, our team is happy to help.